NYCRR Title 10 Part 4 Replaces NY State Emergency Legionella Laws

Posted by Greg Frazier on Wed, Jul 20, 2016 @ 04:56 PM

New Law Passed for Cooling Tower Owners in New York State!

On July 6th, 2016, New York State adopted a new Part 4 to Title 10 of the New York Code, Rules and Regulations entitled Protection Against Legionella. Officially known as NYCRR Title 10 Part 4: Protection Against Legionella, it is now the definitive regulation governing Legionella prevention in New York. This new legislation closely mirrors NYC’s Title 24 Chapter 8 of the Rules of the City of New York and the New York State emergency legislation that it replaces regarding legionella in cooling towers for all buildings and legionella in potable water systems for healthcare facilities throughout New York State. There are however, some significant additions and changes that NY building owners should be aware of. If you are responsible for a cooling tower in the State of New York, including the five boroughs, you are probably going to want to be familiar with this new law.

Read More

Tags: Cooling Tower Water Treatment, Legionella in Cooling Tower, Legionella in Potable Water Systems, Legionella Prevention, New York Cooling Tower Law, Water Treatment Companies, Legionella Water Treatment, new york legionella laws, Water Management Plan, NYCRR Title 10 Part 4

ASHRAE Standard 188 is Approved: Here is What You Need to Know!

Posted by Greg Frazier on Tue, Jun 30, 2015 @ 06:29 PM

It’s official! ANSI/ASHRAE Standard 188-2015 is finally here!  Many industry professionals in the property management, facilities management, healthcare, senior care and building operations industries have been waiting a long time for the release of ASHRAE Standard 188 and we can all finally download our copies today! Publication of Standard 188 coincides with ASHRAE’s Annual Conference taking place in Atlanta GA from June 27-July 1, 2015.

Read More

Tags: Legionella Remediation, Legionnaires' Disease, Legionella in Cooling Tower, Legionella in Potable Water Systems, Cooling Tower Cleaning Service, Legionella Prevention, ASHRAE Standard 188, Commercial Water Treatment Company, Legionella Water Treatment, Legionella Consulting, ASHRAE Standard 188 Consultant

ASHRAE Standard 188 May Change the Way You Think About Legionella and Water Treatment

Posted by Greg Frazier on Sat, Feb 21, 2015 @ 10:25 AM

Recent events in New York City have once again brought Legionnaires Disease onto the radar for many facilities throughout the Northeast.  The latest Legionellosis outbreak reported in NYC has been allegedly linked back to an infected cooling tower in the Bronx.  It has been reported that the facility in question is now under the watchful eye of the New York City Health Department.  Legionella in a cooling tower is a serious issue because of how a cooling tower operates; not only does the bacteria thrive in an under-treated environment, but the the tower mechanism itself acts as the perfect way to dispurse the bacteria in water droplets into the atmosphere.  As you can imagine, attorneys have already threatened to bring suit, and facility managers across the New Your City are re-thinking their protocols for dealing with legionella. Many building owners are trying to figure out if they have the best water treatment company in New York working for them.  There is a very good chance that there were steps that could have been followed that would have prevented this unfortunate event; and if the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) get their way, there soon will be.

Read More

Tags: Cooling Tower Treatment, Legionella Remediation, Cooling Tower Water Treatment, Legionnaires' Disease, Legionella in Cooling Tower, Legionella in Potable Water Systems, Cooling Tower Cleaning Service, Legionella Prevention, HVAC Cleaning Service, ASHRAE Standard 188, Biocides, Biofilm, HVAC System Survey, Best water treatment company in NYC, Water Treatment Services, Cooling Water Chemicals, Legionella, Legionella Water Treatment, Cooling Towers, HVAC Water Treatment Company, Bioslime

Twelve Great Resources for Legionella Prevention and Water Treatment

Posted by Greg Frazier on Wed, Jun 26, 2013 @ 07:28 PM

Severe pneumonia from Legionnaires’ disease may become so serious that hospitalization is required. Severe cases can be fatal. The legionella bacteria that cause Legionnaires’ disease can grow in your facility’s potable drinking water systems, hot tubs, decorative fountains, hot water tanks, and cooling towers. That’s why is so important to know the best practices in treating and maintaining those systems to prevent the legionella bacteria from flourishing in them.  Adopting the best water treatment practices is always the first defense against legionella, especially to reduce the risk of legionella in cooling towers.

Read More

Tags: Water Treatment, Cooling Tower Treatment, Legionella Remediation, Cooling Tower Water Treatment, Legionnaires' Disease, Legionella in Cooling Tower, Legionella in Potable Water Systems, water treatment best practices, Industrial Water Treatment, Water Treatment Services, Cooling Water Chemicals, Legionella, Legionella Water Treatment